No products in the cart.
Million Care OLED Measurement Accuracy
රු 2,590.00
- Rapid and accurate measurement of oxygen saturation of pulse rate and arterial hemoglobin level.
- Compact and light weight, easy to carry, suitable for various finger sizes.
- Display: Blood oxygen SPO2 value, pulse PR value, blood oxygen bar graph, pulse waveform, PI (perfusion index), respiratory rate monitoring parameter (130R), sleeping: monitoring parameter (131R).
- Accurate determination of your oxygen saturation (blood oxygen saturation level), rapid oxygen saturation reading, pulse measurement, and convenient display.
- Blue and yellow display screen, 5 level brightness can be adjusted.
Item will be shipped in 1-2 weeks
Compare
Features:
Rapid and accurate measurement of oxygen saturation of pulse rate and arterial hemoglobin level.
Accurate determination of your oxygen saturation (blood oxygen saturation level), rapid oxygen saturation reading, pulse measurement, and convenient display.
Compact and light weight, easy to carry, suitable for various finger sizes.
Display: Blood oxygen SPO2 value, pulse PR value, blood oxygen bar graph, pulse waveform, PI (perfusion index), respiratory rate monitoring parameter (130R), sleeping: monitoring parameter (131R).
Blue and yellow display screen, 5 level brightness can be adjusted.
Blood oxygen probe and processing display module are integrated. Monitoring parameter SPO2: suitable for all people above 4 years, measuring range of 70-99%.
Oximeter saturation: an important indicator of oxygen condition in the body. It is generally believed that the normal blood oxygen saturation value should not be lower than 94%, and below 94% is considered as insufficient oxygen supply.
Heart Rate: refers to the number of beat per minute of the Heart.The same person’s heart rate slows during quiet or sleep, and increases during exercise or emotional arousal.
Perfusion Index, Pl value reflects the pulsating bloodstream, so it reflects the Perfusion ability.The greater the pulsating blood bloodstream, the more pulsating components, and the greater the PI value.Therefore, PI values are influenced by the measured site (skin, nails, bone, etc.) and the patient’s own perfusion condition (arterial bloodstream).Since the sympathetic nerve affects heart rate and arterial blood pressure (which affects pulse and arterial bloodstream), the body’s neuroregulatory system or mental state also indirectly affects the P value.Therefore, the PI value will be different under different anesthesia.
Respiratory frequency monitoring RR value (130R):Breathing rate is a term to describe the number of breaths per minute.The number of breaths per minute is called the breathing rate.Breathing is a necessary process of gas exchange between the internal and external environment of the human body. The human body inhales oxygen and exhales carbon dioxide through breathing, so as to maintain normal physiological functions.Normal adults take about 16 to 20 breaths per minute.The ratio of respiration to pulse is 1:4, that is, the pulse beat 4 times for every breath.Children breathe faster than adults, up to 20 to 30 times per minute;Newborns breathe at a rate of four breaths per minute.Breathing rate varies with age, , and physiological condition.
Sleep monitoring storage memory function (131R):Sleep record is recorded by waveform function. Up to 8 hours of waveform data can be recorded. And in the way of memory storage, convenient users to investigate data!Data can be provided to professional doctors for effective treatment of sleep disorders.
Specification:
Condition: 100% Brand New
Color: Silver Black
Blood Oxygen Saturation Range: 70% ~ 99%
Pulse Rate Measurement Range: 30BPM~240BPM
Accuracy Of Blood Oxygen Saturation Measurement: ±2% within the range of 70% ~ 99%, ≤70% not defined
Pulse Rate Measurement Accuracy: ±1BPM or ±1% of the measured value (larger value)
Blood Oxygen Saturation Resolution: ±1%
Sleep Monitoring Time: 130R: no, 131R: 8 hours
Power Consumption: less than 30mA
Auto Shutdown: auto shutdown in 8 seconds without finger insertion
Service Temperature: 5C~40℃
Storage Humidity: 15%~80% when working, 10%~80% storage
Atmospheric Pressure: 70Kpa ~ 106Kpa
Battery: 2 x 1.5v AAA (Not included)
Material: ABS + PC
SPO2:
Suitable: for all people above 4 years
Measuring Range: 70-99%
Analytic: 1%
Accuracy: 70%–99%±2%
(PR)BPM:
Measurement Range: 30bpm -250bpm
Accuracy: 1% or 1bpm
Blood Perfusion Indicates Pl:
Measurement Range: 0.2%-30%PI
Analysis: 1%
Package List:
1 x Fingertip Pulse Oximeter
1 x Strap
1 x Manual
No more offers for this product!
General Inquiries
There are no inquiries yet.
Reviews
There are no reviews yet.